Browse all practice questions for the Enphase Solar PV Installation Certification Training Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Enphase Solar PV Installation Certification Training Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is PLC used for in Enphase systems?
  • To ensure you receive all Enphase Enlighten Manager emails, which setting should you configure?
  • Which means of contacting Enphase support are available?
  • Enphase microinverters do not require an EGC (equipment grounding conductor).
  • What energy measurements are viewable when selecting the graph view and an ENERGY time period?
  • When using Enlighten Manager to troubleshoot CT installation errors, you have the option to select which source data is shown in Enlighten Manager under the Graph tab of the affected site. Either microinverter measurements or meter measurements.
  • In order to measure the current from the utility, the CT arrow should face which direction?
  • Which of the following is not a typical benefit of a dedicated solar sub-board?
  • Which conductor size is used for the largest conductor size listed among #14 AWG, #12 AWG, #10 AWG, and #8 AWG?
  • A summary report does not include any details about that microinverter status.
  • The Graph tab can display either microinverter measurements or meter measurements for the affected site.
  • If one microinverter in a solar PV system fails, what will occur?
  • The CT operates by passing the conductor through the CT, creating a magnetic field that induces a current in the CT secondary windings. This current is measured by the Envoy to calculate production and consumption values.
  • ______ are marked with arrows to indicate the expected flow of current.
  • If needing to jump across a gap (i.e., skylight) between two arrays, what simple method can be used within Q wiring?
  • Which of the following is an Internet Protocol used by Enphase products?
  • When is the summary report available?
  • To disable (or enable) power production for a given system you can select the "Devices" tab, select the Envoy, then select the "Disable Power Production" button.
  • Which statement about the Systems List tab is true?
  • To view microinverter data and animations for six metrics per module, you must use the Enphase Installer Toolkit app.
  • Which CT is a split-core?
  • In a residential PV system, production CTs are required to measure PV generation?
  • When configuring the production meter, what 2 things can you verify within the Installer Toolkit that the production CT is measuring PV production correctly?
  • Which statement about production CT verification is true?
  • Which report shows grid profile settings per microinverter?
  • What do the letters AP mean when referring to AP mode?
  • What is used to seal, insulate and protect cut Q cable ends?
  • Which statement best reflects safe ladder use?
  • Enphase best practice regarding site activation timing?
  • The grid profile can be selected ahead of time in Enlighten Manager to reduce mistakes by field installers who work in multiple areas.
  • Which component provides online monitoring and performance data for the Enphase system?
  • Which option is NOT a Summary/Kiosk display view option?
  • What is the Internet Protocol used for?
  • Enphase Service-on-the-Go can be accessed using the Installer Toolkit.
  • CT polarity is determined by the direction of which winding?
  • Which statement best describes the need for separate Enlighten accounts?
  • Enlighten Manager is accessed via web browser and is intended for which users?
  • True or False: The IQ Combiner 3 and 3C is rated for up to 80 amps of PV and storage.
  • Where would you adjust alert email preferences?
  • How often should you check your fall protection equipment?
  • What does a CT measure?
  • Which platform is used to access performance data for a system you have built?
  • Which government agency recommends the use of microinverters for solar PV installation in hurricane-prone areas?
  • True or false: MyEnlighten is the web platform and Installer Toolkit is the mobile app platform for system owners to monitor their system.
  • How many points of contact must you keep on a ladder to be considered safe?
  • The Systems List tab can be modified to show different criteria under the 'change columns' feature. For example, by owner name, location or equipment used.
  • Is a terminator cap required on all exposed, cut Q cable ends?
  • AP in AP mode stands for which term?
  • True or False: Creating the virtual array can only be done in the Installer Toolkit?
  • What does a filled green circle indicate in the app?
  • When using the Enlighten Manager 'Graphs' tab to troubleshoot CT installation and metering errors, it can be helpful to change which source data comes from. To select the data source, go to the settings tab then select either microinverter measurements or meter (CT) measurements.
  • The _____________ is used to connect the customer's site to Enlighten?
  • Which set correctly lists the three core components of an Enphase PV system?
  • What type of animation can be found in the Systems view tab?
  • To verify wire phasing, two measurements are taken: L1 at the main breaker and L1 at the Envoy's power terminal block. If phasing is correct, what should the readings be?
  • Which of the following is true about the IQ Combiner 3/3C's breaker capacity?
  • Which Envoy connection points are used for CT wiring?
  • In the context of the commissioning process, which statement about the virtual array is accurate?
  • Activation can be created at the job site in a minute or two using the Installer Toolkit app.
  • Which device provides data to Enlighten and can monitor system performance?
  • If you wanted to change ALERT email settings from Enphase Enlighten Manager you'd select the desired notification preferences under ALERT EMAIL PREFERENCES from the SETTINGS tab.
  • Do solar panels deliver a constant STC-rated output under typical installations?
  • The Live Status view provides which of the following?
  • Which statement accurately describes the purpose of the Enphase disconnecting tool?
  • The Settings Tab is the default or home page view after logging in to Enlighten Manager. Here you can view your fleet of systems.
  • Enphase recommends keeping Vrise under what percentage from the point of supply to the AC isolator?
  • Why must each user have their own Enlighten account?
  • Which statement best describes Enlighten's role in the activation process?
  • Which statement is true about selecting the 'load only' option when consumption CTs carry current from both solar and loads?
  • Which cord grip is recommended for the Q cable entering a junction box?
  • True or False: Setting the tariff rate schedule is a required step during the commissioning process?
  • Which of the following is true about activation in the installation process?
  • Which of the following is a feature of the IQ Combiner 3 and 3C?
  • Which component is used to connect the installation site to Enlighten?
  • Solar Professional using Enlighten Manager can simulate the same view a System owner sees.
  • If the (company) account tab is not visible in Enlighten Manager, clicking on the dashboard view, returning to the default screen will help restore account and other tab options.
  • Fall protection safety statement: which is true?
  • What is the purpose of a CT in solar PV monitoring?
  • Which item can be used to verify CT polarity during installation?
  • An Enlighten user account is not required to access the Installer Toolkit?
  • Which statement about CT readings and Envoy calculations is correct?
  • Envoy to Enlighten using an internet connection.
  • Which tab contains the alert email preferences option?
  • Because the systems view tab can show Energy production per module over time it could easily reveal shade impacts due to a satellite dish or other obstruction.
  • True or False: When setting up the consumption CTs, you can use the L1, L2 measurements to aid you in determining potential installation errors with the CTs?
  • Which statement is true about the terminator cap?
  • Which statement about Q Cable tensioning is correct?
  • Which of the following are features of Enphase Enlighten monitoring?
  • You have a given solar module brand and model in mind for use at a given installation site, when choosing microinverters what is an essential specification to review and why?
  • True or false: Fall protection can save your life.
  • Voltage rise in microinverter systems is measured from which start to end point?
  • In a single-phase installation using a 1-phase Q relay, what is the maximum circuit breaker current size for each PV AC branch circuit?
  • Which of the following is a Powerline Communications Protocol used by Enphase products?
  • Which statement best describes designing microinverter and solar panel pairing based on power output?
  • Which statement describes the activation process in relation to Enlighten?
  • Which statement about the combiner 3's built-in Envoy is true?
  • Which statement accurately describes Enlighten Manager's capabilities?
  • Which methods can be used to assign microinverter serial numbers to the virtual array?
  • The 'ABC's' of Fall Protection stands for_________
  • Which statement describes the function of Enphase inverters?
  • If the CTs are installed in a location such that only current supplying the loads is passing through, you should select the 'load only' option.
  • AP mode is used for direct connection between the Installer Toolkit and the Envoy.
  • Enphase Q Raw Cable uses which conductor size?
  • A key consideration when mounting microinverters on a rail is orientation. Which option correctly describes this orientation?
  • Which factor primarily impacts the maximum quantity of microinverters per AC branch circuit?
  • Which of the following steps is not required during commissioning?
  • What must you take in to consideration so that the inverter doesn't hit the rail when mounting the module?
  • Enlighten Manager is used to commission systems at the job site.
  • Which tool uses activation to link the customer and site to Enphase?
  • When mounting microinverters on the rail, which orientation should the bracket face?
  • What is the primary function of a microinverter?
  • Which description best reflects when the installation sticker map should be completed?
  • It's essential to verify microinverter settings in the SUMMARY provided in the Installer Toolkit app as the reports in Enlighten Manager cannot display the Grid Profile settings per microinverter.
  • A completed step is shown by which UI element?
  • Where is all equipment for a site listed in Enlighten Manager?
  • Under the Settings tab, which source can you choose for energy and power readings: microinverters or CT metering hardware?
  • What color are the CT secondary wires connected to the Envoy?
  • The Live Status view is _______.
  • Where would you change ALERT EMAIL PREFERENCES?
  • Which statement best describes how serial numbers can be assigned to the virtual array?
  • Which component serves as the communications hub delivering data to the cloud?
  • When selecting microinverters for a given solar panel model, which factor is essential and why?
  • What is the relationship between temperature and solar panel output?
  • Which installer tool is used for on-site configuration and troubleshooting in Enphase installations?
  • What is the maximum number of circuits that can be installed in an Enphase Combiner 3?
  • Under the (company) account tab, which items can be updated?
  • When sending the summary report email, what else would it be good to attach in the email aside from the summary report pdf?
  • Which statement best describes the role of microinverters in an Enphase system?
  • How many models are in the IQ7 inverter line?
  • If using Wi-Fi from an Envoy for internet connection, what must NOT be used to mount the Envoy into?
  • Which document is used to connect the customer’s site to Enlighten?
  • As compared to the IQ Combiner 3 the IQ Combiner 3C______.
  • When installing an AC module system, the installation map can be created at the end, similar to a stand-alone (separate) microinverter system?
  • The Enphase Q cable plugs into which component?
  • Enphase Q Cable compatibility with other manufacturers is described as which?
  • Can Enphase Q Raw cable be used to jumper between two arrays?
  • Enphase Enlighten monitoring can display battery storage information if installed.
  • True or False: Setting the consumption CT type (load only or load with solar) incorrectly won't affect how the envoy calculates values?
  • The Envoy reads the CT secondary current to calculate production and consumption values.
  • Which communication protocol does the Envoy use to communicate with the microinverters?
  • A designer observes that a system design exceeds 2% Vrise (voltage rise). What design strategies can be used to reduce Vrise?
  • Which of these best practices should be created prior to the day of installation?
  • What is the meaning of the green cloud in the Enlighten app?
  • Real-world solar panel outputs are typically lower than STC-rated values due to what conditions?
  • Consumption CTs monitor what in a PV system?
  • What is the correct statement about creating activation prior to installation?
  • What is the ratio between microinverters and PV modules in an Enphase PV system?
  • Are Eaton BR 2-pole breakers the only breakers approved for use in the IQ Combiner box?
  • How can you create an Enphase site activation?
  • The Envoy collects data from microinverters every 15 minutes using PLC.
  • Which platform provides system performance data for an installed Enphase system?
  • Which tool is used for system verification and commissioning?
  • Which statement about when to create site activation aligns with Enphase best practice?
  • Which connections are active to the Envoy?
  • Which statement describes the purpose of a solar sub-board?
  • True or False: The CT's primary conductor must pass through the CT core to obtain an accurate measurement.
  • When wiring an Enphase PV system, voltage and current readings must be taken from which?
  • Activation workflow is intended to speed up on-site installation by pre-configuring systems.
  • To save time on a jobsite installation and improve accuracy, it's a best practice to create an 'Activation' and build the 'virtual array' in the office using Enlighten Manager.
  • How often does the Envoy collect performance data from the microinverters using the PLC protocol?
  • To set the energy and power data source, you can choose between microinverters and CT metering readings.
  • Which platform is the web platform for system owners to monitor their system?
  • What is a single point of failure?
  • Which conductor(s) must be routed through the production CT?
  • Which protocol does the Envoy use to collect performance data from microinverters?
  • The Enlighten Mobile app is available for which smartphone and tablet devices?
  • To prepare an AC Module for installation, the microinverter must be pulled out from the mounting bracket and snapped into the installation ready position.
  • You cannot create a support case using the Installer Toolkit.
  • Which statement about the Enphase Installer Toolkit app is accurate?
  • How is creating the installation sticker map different with an AC module system vs a stand-alone rail mounted inverter?
  • When is CT installation required?
  • AP mode can be used to connect the Installer Toolkit to the Envoy for direct access.
  • What are the benefits of installing a dedicated solar sub-board?
  • The available detailed display view options in the Summary/Kiosk view tab are NOT. Which item is NOT an option to display in Summary View?
  • Power and energy animations are included in Enlighten Manager, and to view microinverter data of six metrics per microinverter, solar professionals need to use the Enphase Installer Toolkit app.
  • Activation is optional in order to monitor an Enphase system in the Enlighten platform.
  • Which component is used to measure current in a PV system for Envoy monitoring?
  • What is a current transformer?
  • Which statement about solar panels is true?
  • Which Enphase portal is used for monitoring and activation linking?
  • In a multiphase installation using a multiphase phase Q relay and 3-phase wiring, what is the maximum circuit breaker current per PV AC branch circuit?
  • Enlighten Manager is for______?
  • The Enlighten Manager Dashboard is where you configure user account settings and specify PV and Energy storage operation modes.
  • The installation map for an AC module system can be created at the end.
  • The Installer Toolkit supports only mobile devices which use either an Android OS or Apple iOS?
  • It is a best practice to create the __________ prior to the day of installation.
  • A list of microinverters can be found under the 'Devices' tab.
  • What device collects data from the array and uploads that data to the web?
  • Which tool is best for spotting sites that may need service or attention?
  • In a solar array with Enphase microinverters, should all panels have the same orientation for maximum energy production?
  • True or False: If the main service conductors are not accessible, you will not be able to use consumption CTs.
  • Return Requests and other self-service items options are available from the settings menu and elsewhere such as when directly reviewing a specific piece of hardware under Devices or Energy and Power views.
  • Enphase support can be reached by live chat, webform (email reply) and phone.
  • Which of the following is a conductor size for the Enphase Q cable?
  • Which statement correctly describes the IQ Combiner 3C compared to the IQ Combiner 3?
  • Which statement about the Envoy's communication with microinverters is true?
  • What is the maximum 2 pole breaker size allowed for each Q Cable (12AWG) PV AC branch circuit?
  • Under the Systems tab, change columns options can only be changed by calling Enphase customer support.
  • In real-world solar installations, outputs are typically lower than STC-rated values due to what conditions?
  • What is the Envoy's role in CT measurements?
  • What causes a current transformer to generate a measurable signal for the Envoy?
  • Which statement about user accounts is true?
  • Voltage rise can be reduced by using larger wire sizes, reducing the microinverter quantity or by center feeding AC branch circuits.
  • What must be considered so microinverters don't hit rails when mounting AC modules?
  • Enphase's disconnecting tool allows you to____________
  • Which statement describes consumption monitoring?
  • What is the maximum circuit breaker current per PV AC branch circuit in a multiphase installation using 3-phase wiring?
  • Which option describes the method to assign serial numbers to the virtual array?
  • Which data sources can be shown in the Graph tab for the affected site?
  • Which statement best describes the purpose of a CT in the Envoy monitoring system?
  • Which of the following is NOT a core component of an Enphase PV system?
  • When using a production CT, what PV branch circuit conductors are used to measure PV generation?
  • Terminator caps make cut Q Cable ends safe and waterproof.
  • The IQ Envoy is able to communicate with:
  • The Dashboard can be used for a quick reference to identify sites that may need service/attention.
  • Refer to the image: the Enlighten Manager Services Tab shown up top is for warranty repairs only.
  • What governing body sets federal and statewide safety standards?
  • How many consumption CTs are required for consumption monitoring?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy